How do I compare the same channel from several measurement files?¶
UniPlot offers three ways to put the same channel from several test runs into one diagram: drag it once and plot it from all loaded files, load a new file on top of an existing curve with the import type Add File, or let File=>Channel Quick View create the overlay plots for a list of files.
Full load torque over engine speed from five test files (sample files
Test1.xls to Test5.xls) in one diagram.¶
How it works¶
Drag and drop from all files
Import the files with File=>Import Data.
If the document already contains curves from different files, UniPlot offers to plot the dragged channel from all of these files when you drag it into the page. A dialog box lets you choose the files to include.
Add File
Plot the channels of the first file and select one of its curves.
Import the next file and choose the dataset type Add File in the Data Browser, then click Load.
UniPlot copies all curves that came from the first file and fills the copies with the data of the new file. A dialog box sets the curve style, so every file gets its own color.
Channel Quick View
Choose File=>Channel Quick View and select the data files.
Select the x channel and the y channels. UniPlot creates overlay plots of the selected channels for all files, based on a template.
Why it helps¶
No copying of data between files: each curve keeps its link to its data file.
Add File repeats the whole page layout, so a page with five diagrams shows the next test in all five diagrams at once.
Good to know¶
The import type Replace File works the other way round: it replaces the data of all curves of a file instead of adding new ones.
To swap the data files of a finished page or document, use Data=>Data Exchange (Page) or Data=>Data Exchange (Document).
For dozens or hundreds of files the comparison can be automated, see Automation, Scripting & Batch Processing.